How to Charge Li-ion with a Parasitic Load
Charging a battery is simple but the complexity rises when a parasitic load is present during charge. Depending on battery chemistry, the charge process goes through several stages, and with lithium-ion Stage 1 consists of a constant current (CC) charge that brings the battery to roughly 70 percent state-of-charge (SoC). The cell reaches 4.20V/cell, a common voltage limit for Li-ion, after which Stage 2 continues by applying a constant voltage (CV) charge. The current begins to drop as the battery saturates. Full-charge is reached when the current decreases to typically 0.05C, which is one-twentieth of the rated ampere-hour. Li-ion cannot absorb overcharge and no charge is applied in Stage 3. Figure 1 illustrates typical voltage, current and capacity signatures of the CCCV charge.
Figure 1: Charge regime of the lithium-ion battery.
Stage 1 applies bulk charge under constant current (CC).
Stage 2 completes the charge under constant voltage (CV) as part of saturation charge.
Stage 3 is the ready mode with no charge applied.
Courtesy of Cadex
The CCCV method is also used to charge Lead acid with the difference that a float charge is applied in Stage 3 to keep the battery at full charge and to prevent sulfation. Nickel-based batteries receive trickle charge when fully charged to compensate for self-discharge. The Li-ion system is so efficient that excess energy has nowhere to go when the battery is fully charged. Turning the charge current off keeps the battery stable and enables the voltage to neutralize. A continuous float charge, also known as high-voltage-hold, increases the Li-ion battery to above the specified upper cut-offs potential. This would possibly produce gas; possibly cause a breakdown of cell components and probably shorten battery life and compromise safety.
Type of Battery Usage
Battery usage can be categorized into three groups. The most basic is the Detachable Mode where the battery is charged outside the device unaffected by a parasitic load. Applications include mobile radios, power tools, drones and general instrumentations. This Detached Mode enables the most simplistic charge method because the battery is independent from a device. Most commercial charging chips are designed to operate in this mode.
A growing usage pattern is the Contained Mode in which the battery is charged in the equipment. Smartphone, laptops and some medical devices are examples. The battery is charged in the device by connecting to the grid. The available AC power is divided into charging the battery and operating the device. When fully charged, the battery disconnects from the charger but may from time to time receive a topping charge. This typically occurs when the state-of-charge drops to 93 percent.
The third group is the Attached Mode where the battery is installed in a device. Typical applications are vehicles delivering hotel load and starting the engine. In the Attached Mode, the battery becomes part of an integrated system that is charged during the operation. Some medical, military and industrial devices also operate in Attached Mode providing vital functions. Table 2 summarizes battery usages in different charging environments.
| Group | Charge Method | Applications |
| Detached Mode | Battery is charged outside the device with no parasitic load. Charger follows the signature of the battery. | Mobile radios, power tools, drones |
| Contained Mode | Battery is charged in equipment. Built-in charger charges battery independently of circuit; disconnects battery when ready. | Smartphone, laptops, small medical devices |
| Attached Mode | Battery is installed in a device. Vital functions draw parasitic loads. Charging by topping charge or holding voltage at different levels. | Vehicles, airplanes, some medical devices |
Table 2: Battery usage in different charging environments.
Parasitic loads add to charging complexity.
Parasitic Load
The presence of a continuous parasitic load on a battery complicates the charging process. It should be noted that most devices draw some parasitic load but the current is low and may consist of protection circuit for the Li-ion battery, memory back-up or running a clock. This does not distort the charge routine and can in most cases be ignored. However, the parasitic load in the Attached Mode can be high and distort the saturation signature in Stage 2. Such interference in the charging regime requires an alternate full-charge detection mechanism.
Possible solutions are reducing the charge current in Stage 2 for some time, then turning the charge off and applying a topping charge when the state-of-charge drops to 93 percent. Another method is keeping the cell at the 4.20V/cell level. This would be the simplest technique but most Li-ion manufacturers do not approve of this method for safety and longevity reasons. A further option is lowering the charge from the customary 4.20V/cell to 4.10V/cell. This reduces capacity and cell manufacturers consider this viable but are not totally comfortable.
Scientists are studying the behavior of Li-ion at various high-voltage-holds as a function of electrolyte additives and choice of active materials. Unofficial findings show that cycling cells with extended hold times at 4.20V/cell does not lead to lithium plating with quality cells. However lower grade cells could develop high impedance, which can result in Li-plating when held at 4.20V/cell for an extended period of time at elevated temperatures of 40°C.
Keeping Li-ion at high-voltage-hold is a sensitive issue. Few technical papers have been published that suggest how to correctly charge a battery with a parasitic load, nor do battery manufacturers share best practices. It is known that float charging at elevated temperature can cause a breakdown of cell components, which can potentially lead to an electrical short in the cell. Findings reveal that this defect does not necessarily relate to lithium plating that occurs when exceeding the charge voltage or when charging below freezing. Other harmful effects are at work that requires further examination.
Component breakdown can be reduced with electrolyte additives. Each battery manufacturer has its own secret sauce and is hesitant to publish the ingredients. As smoking and lack of exercise affects the health of each person differently, so also is no consistent information available when charging a specific Li-ion system with a parasitic load. There appears to be a lack of information on the effect of high-voltage-hold on Li-ion, especially when operating at elevated temperature and when fast-charging.
Let’s look at lead acid, a system that shares similarities with Li-ion with charging but is more forgiving with overcharge. In Stage 1, lead acid charges to 2.40V/cell. Applying a fully saturated charge at Stage 2 is important to prevent sulfation. Instead of cutting the charge current to zero when ready, Stage 3 lowers the voltage from 2.40V/cell to 2.25V/cell to maintain full-charge. Keeping lead acid at the high 2.40V/cell would cause gassing and promote plate corrosion. Applying a voltage reduction is important especially in stationary applications where the battery is under continuous charge.
The charging system in a vehicle brings the battery to typically 14.40V (2.40V/cell) with no provision to lower the voltage when fully charged. Reducing the voltage to 13.50V (2.25V/cell) on a long road trip would be preferable but lead acid is forgiving and tolerates this condition by receiving rest when the vehicle is parked.
Starter batteries are often replaced with LiFePO (Li-Phosphate) running on the same charging system. Four cells in series produce 12.80V, a similar voltage to six 2V lead acid cells in series. Each of the four Li-phosphate cell tops at 3.60V, which is the correct full-charge voltage. At this point, the charge should be disconnected but the topping charge of the vehicular charger continues while driving.
Li-phosphate is tolerant to some overcharge; however, keeping the voltage at 14.40V for a prolonged time could stress the battery. Time will tell how durable Li-Phosphate will be when operating with a regular charging system programmed for lead acid. Li-phosphate batteries are also being installed in wheelchairs, scooters, golf cars and computers-on-wheels in hospitals. It is wise to assure charger compatibility when replacing lead acid with Li-phosphate.
An aircraft shares similarities with a vehicle in that both systems operate in the Attached Mode. As in a vehicle, the battery in an aircraft can be disconnected once the auxiliary generator provides power. An incident occurred when a nickel-cadmium (NiCd) battery overheated on a Boeing 777 in mid-flight. The circuit breaker was pulled without incident to separate the battery from the system.
Pilots demand that the battery be at full charge at all times. With NiCd, the common on-ship battery of passenger airplanes, this is no problem, but the Boeing 787 Dreamliner is equipped with Li-ion operating in Attached Mode. In 2013 this battery did indeed develop problems but experts say that the onboard battery fires were not caused by incorrect charging but by battery flaws. Whereas the failure rate of a quality Li-ion battery produced by major manufacturers is around 1 in 10 million, the early Boeing 787 batteries had a failure rate of 3 in 800.
In the early 1970s, the National Transportation Safety Board reported several battery incidents per year involving the then new NiCd, but none led to casualties. A redesign eventually made NiCd safe and similar improvements will also be made with Li-ion on board of an aircraft.
One big advantage of Li-ion apart from higher specific energy is their low maintenance. The Boeing engineers did, however, reach out to the automotive sector to learn how large Li-ion batteries are managed in electric vehicles. They discovered that an EV battery has some 50 sensing points for safety; the Boeing 787 had fewer than ten. This shortcoming has now been corrected.
Summary
How should a Li-ion battery be charged with a parasitic load? A solution is high-voltage-hold by applying a float charge in the Attached Mode, but this removes one level of safety redundancy, which concerns battery manufacturers. Should the float charge go out of control, the cell gets overcharged and lithium plating will occur. It is also known that high-voltage-hold at elevated temperature causes a breakdown of cell components. The long-term effects in practical use may not yet be fully understood.
The answer to safely operate Li-ion in the Attached Mode may lay in the choice of electrolyte additives as well as lowering the full charge state. The stress level of Li-ion is lowest between a state-of-charge of 30 and 80 percent. EVs use this preferred SoC bandwidth to achieve extraordinary long battery life, however the packs must be oversized to compensate for the reduced capacity.
Li-ion is optimized for various applications that range from high-energy single cells for consumer products, to sturdy multi-cell configurations for medical, military and mobility use, and to high power cells for power tools. Operating Li-ion in the Attached Mode is a growing market and battery manufacturers will need to take note and deliver a product that will serve this new application.
About the Author
Isidor Buchmann is the founder and CEO of Cadex Electronics Inc. For three decades, Buchmann has studied the behavior of rechargeable batteries in practical, everyday applications, has written award-winning articles including the best-selling book “Batteries in a Portable World,” now in its fourth edition. Cadex specializes in the design and manufacturing of battery chargers, analyzers and monitoring devices. For more information on batteries, visit www.batteryuniversity.com; product information is on www.cadex.com.
Last Updated: 18-Sep-2017
Batteries In A Portable World
The material on Battery University is based on the indispensable new 4th edition of "Batteries in a Portable World - A Handbook on Rechargeable Batteries for Non-Engineers" which is available for order through Amazon.com.
Find An Article
Table of Contents
-
Introduction 4>
- BU-001: Sharing Battery Knowledge
- BU-002: Introduction
- BU-003: Dedication
-
Crash Course on Batteries 4>
- BU-101: When Was the Battery Invented?
- BU-102: Early Innovators
- BU-103: Global Battery Markets
- BU-103a: Battery Breakthroughs: Myth or Fact?
- BU-104: Getting to Know the Battery
- BU-104a: Comparing the Battery with Other Power Sources
- BU-104b: Battery Building Blocks
- BU-104c: The Octagon Battery – What makes a Battery a Battery
- BU-105: Battery Definitions and what they mean
- BU-106: Advantages of Primary Batteries
- BU-106a: Choices of Primary Batteries
- BU-107: Comparison Table of Secondary Batteries
-
Battery Types 4>
- BU-201: How does the Lead Acid Battery Work?
- BU-201a: Absorbent Glass Mat (AGM)
- BU-201b: Gel Lead Acid Battery
- BU-202: New Lead Acid Systems
- BU-203: Nickel-based Batteries
- BU-204: How do Lithium Batteries Work?
- BU-205: Types of Lithium-ion
- BU-206: Lithium-polymer: Substance or Hype?
- BU-208: Cycling Performance
- BU-209: How does a Supercapacitor Work?
- BU-210: How does the Fuel Cell Work?
- BU-210a: Why does Sodium-sulfur need to be heated
- BU-210b: How does the Flow Battery Work?
- BU-211: Alternate Battery Systems
- BU-212: Future Batteries
- BU-214: Summary Table of Lead-based Batteries
- BU-215: Summary Table of Nickel-based Batteries
- BU-216: Summary Table of Lithium-based Batteries
- BU-217: Summary Table of Alternate Batteries
- BU-218: Summary Table of Future Batteries
-
Packaging and Safety 4>
- BU-301: A look at Old and New Battery Packaging
- BU-301a: Types of Battery Cells
- BU-302: Series and Parallel Battery Configurations
- BU-303: Confusion with Voltages
- BU-304: Why are Protection Circuits Needed?
- BU-304a: Safety Concerns with Li-ion
- BU-304b: Making Lithium-ion Safe
- BU-304c: Battery Safety in Public
- BU-305: Building a Lithium-ion Pack
- BU-306: What is the Function of the Separator?
- BU-307: How does Electrolyte Work?
- BU-308: Availability of Lithium
- BU-309: How does Graphite Work in Li-ion?
- BU-310: How does Cobalt Work in Li-ion?
- BU-311: Battery Raw Materials
-
Charge Methods 4>
- BU-401: How do Battery Chargers Work?
- BU-401a: Fast and Ultra-fast Chargers
- BU-402: What Is C-rate?
- BU-403: Charging Lead Acid
- BU-404: What is Equalizing Charge?
- BU-405: Charging with a Power Supply
- BU-406: Battery as a Buffer
- BU-407: Charging Nickel-cadmium
- BU-408: Charging Nickel-metal-hydride
- BU-409: Charging Lithium-ion
- BU-409a: Why do Old Li-ion Batteries Take Long to Charge?
- BU-409b: Charging Lithium Iron Phosphate
- BU-410: Charging at High and Low Temperatures
- BU-411: Charging from a USB Port
- BU-412: Charging without Wires
- BU-413: Charging with Solar, Turbine
- BU-413a: How to Store Renewable Energy in a Battery
- BU-414: How do Charger Chips Work?
- BU-415: How to Charge and When to Charge?
-
Discharge Methods 4>
- BU-501: Basics about Discharging
- BU-501a: Discharge Characteristics of Li-ion
- BU-502: Discharging at High and Low Temperatures
- BU-503: Determining Power Deliver by the Ragone Plot
- BU-504: How to Verify Sufficient Battery Capacity
-
"Smart" Battery 4>
- BU-601: How does a Smart Battery Work?
- BU-602: How does a Battery Fuel Gauge Work?
- BU-603: How to Calibrate a “Smart” Battery
- BU-603a: Calibrating SMBus Batteries with Impedance Tracking
- BU-604: How to Process Data from a “Smart” Battery
- Testing and Calibrating Smart Batteries
-
From Birth to Retirement 4>
- BU-701: How to Prime Batteries
- BU-702: How to Store Batteries
- BU-703: Health Concerns with Batteries
- BU-704: How to Transport Batteries
- BU-704a: Shipping Lithium-based Batteries by Air
- BU-704b: CAUTION & Overpack Labels
- BU-704c: Class 9 Label
- BU-704d: NFPA 704 Rating
- BU-704e: Battery for Personal and Fleet Use
- BU-705: How to Recycle Batteries
- BU-705a: Battery Recycling as a Business
- BU-706: Summary of Do's and Don'ts
-
How To Prolong Battery Life 4>
-
General 4>
- BU-801: Setting Battery Performance Standards
- BU-801a: How to Rate Battery Runtime
- BU-801b: How to Define Battery Life
- BU-802: What Causes Capacity Loss?
- BU-802a: How does Rising Internal Resistance affect Performance?
- BU-802b: What does Elevated Self-discharge Do?
- BU-802c: How Low can a Battery be Discharged?
- BU-803: Can Batteries Be Restored?
- BU-803a: Cell Matching and Balancing
- BU-803b: What causes Cells to Short?
- BU-803c: Loss of Electrolyte
-
Lead Acid 4>
- BU-804: How to Prolong Lead-acid Batteries
- BU-804a: Corrosion, Shedding and Internal Short
- BU-804b: Sulfation and How to Prevent it
- BU-804c: Acid Stratification and Surface Charge
- BU-805: Additives to Boost Flooded Lead Acid
- BU-806: Tracking Battery Capacity and Resistance as part of Aging
- BU-806a: How Heat and Loading affect Battery Life
-
Nickel-based 4>
- BU-807: How to Restore Nickel-based Batteries
- BU-807a: Effect of Zapping
-
Lithium-ion 4>
- BU-808: How to Prolong Lithium-based Batteries
- BU-808a: How to Awaken a Sleeping Li-ion
- BU-808b: What Causes Li-ion to Die?
- BU-808c: Coulombic and Energy Efficiency with the Battery
- BU-809: How to Maximize Runtime
- BU-810: What Everyone Should Know About Aftermarket Batteries
- BU-811: Assuring Minimum Operational Reserve Energy (MORE)
-
Battery Testing and Monitoring 4>
- BU-901: Fundamentals in Battery Testing
- BU-901b: How to Measure the Remaining Useful Life of a Battery
- BU-902: How to Measure Internal Resistance
- BU-902a: How to Measure CCA
- BU-903: How to Measure State-of-charge
- BU-904: How to Measure Capacity
- BU-905: Testing Lead Acid Batteries
- BU-905a: Testing Starter Batteries in Vehicles
- BU-905b: Knowing when to Replace a Starter Battery
- BU-906: Testing Nickel-based Batteries
- BU-907: Testing Lithium-based Batteries
- BU-907a: Battery Rapid-test Methods
- BU-907b: Advancements in Battery Testing
- BU-907c: Cloud Analytics in Batteries
- BU-908: Battery Management System (BMS)
- BU-909: Battery Test Equipment
- BU-910: How to Repair a Battery Pack
- BU-911: How to Repair a Laptop Battery
- BU-915: Testing Battery with EIS
- BU-916: Deep Battery Diagnostics
- BU-917: In Search for Performance Transparency with Batteries
- BU-918: Battery Endurance Plan
-
Amazing Value of a Battery 4>
- BU-1001: Batteries in Industries
- BU-1002: Electric Powertrain, then and now
- BU-1002a: Hybrid Electric Vehicles and the Battery
- BU-1002b: Environmental Benefit of the Electric Powertrain
- BU-1003: Electric Vehicle (EV)
- BU-1003a: Battery Aging in an Electric Vehicle (EV)
- BU-1004: Charging an Electric Vehicle
- BU-1005: Does the Fuel Cell-powered Vehicle have a Future?
- BU-1006: Cost of Mobile and Renewable Power
- BU-1007: Net Calorific Value
- BU-1008: Working towards Sustainability
- BU-1009: Battery Paradox - Afterword
-
Information 4>
- BU-1101: Glossary
- BU-1102: Abbreviations
- BU-1103: Bibliography
- BU-1104: About the Author
- BU-1105: About Cadex (Sponsor)
- BU-1106: Author's Creed
- BU-1107: Disclaimer
- BU-1108: Copyright
-
Learning Tools 4>
- BU-1501 Battery History
- BU-1502 Basics about Batteries
- BU-1503 How to Maintain Batteries
- BU-1504 Battery Test & Analyzing Devices
- BU-1505 Short History of Cadex
-
Battery Articles 4>
- Perception of a Battery Tester
- Green Deal
- Risk Management in Batteries
- Predictive Test Methods for Starter Batteries
- Why Mobile Phone Batteries do not last as long as an EV Battery
- Battery Rapid-test Methods
- How to Charge Li-ion with a Parasitic Load
- Ultra-fast Charging
- Assuring Safety of Lithium-ion in the Workforce
- Diagnostic Battery Management
- Tweaking the Mobile Phone Battery
- Battery Test Methods
- Battery Testing and Safety
- How to Make Battery Performance Transparent
- Battery Diagnostics On-the-fly
- Making Battery State-of-health Transparent
- Batteries will eventually die, but when and how?
- Why does Pokémon Go rob so much Battery Power?
- How to Care for the Battery
- Tesla’s iPhone Moment — How the Powerwall will Change Global Energy Use
- Painting the Battery Green by giving it a Second Life
- Charging without Wires — A Solution or Laziness
- What everyone should know about Battery Chargers
- A Look at Cell Formats and how to Build a good Battery
- Battery Breakthroughs — Myth or Fact?
- Rapid-test Methods that No Longer Work
- Shipping Lithium-based Batteries by Air
- How to make Batteries more Reliable and Longer Lasting
- What causes Lithium-ion to die?
- Safety of Lithium-ion Batteries
- Recognizing Battery Capacity as the Missing Link
- Managing Batteries for Warehouse Logistics
- Caring for your Starter Battery
- Giving Batteries a Second Life
- How to Make Batteries in Medical Devices More Reliable
- Possible Solutions for the Battery Problem on the Boeing 787
- Impedance Spectroscopy Checks Battery Capacity in 15 Seconds
- How to Improve the Battery Fuel Gauge
- Examining Loading Characteristics on Primary and Secondary Batteries
-
Language Pool 4>
- BU-001: Compartir conocimiento sobre baterías
- BU-002: Introducción
- BU-003: Dedicatoria
- BU-104: Conociendo la Batería
- BU-302: Configuraciones de Baterías en Serie y Paralelo
-
Batteries in a Portable World book 4>
- Change-log of “Batteries in a Portable World,” 4th edition: Chapters 1 - 3
- Change-log of “Batteries in a Portable World,” 4th edition: Chapters 4 - 10