Consumers are the first to hear about an apparent battery breakthrough. To get top media attention, the new super battery promises to also satisfy the need for electric vehicle (EV). Personal mobility is an emotional issue that cannot be suppressed, even if it harms the environment. The industrial space, on the other hand, is more conservative and it appears to lag behind. Not so. Industry is rational and understands the many constraints of the battery by focusing on reliability, economy, longevity and safety.
Batteries for Traction
Wheelchairs, scooters and golf cars mostly use lead acid batteries. Even though heavy, lead acid works reasonably well and only moderate attempts are made to switch to other systems Li-ion will be a natural alternative in many applications.
Although Li-ion is more expensive than lead acid, the cycle cost can be lower because of the longer life. A further advantage of Li-ion over lead- and nickel-based batteries is the low maintenance. Li-ion can be left at any state-of-charge without adverse side effects. In contrast, NiCd and NiMH need an occasional full discharge to prevent memory and lead acid requires a saturated charge to prevent sulfation.
Most wheelchairs and golf cars are still powered with lead acid, so are forklifts. With forklifts, the heavy weight is less of an issue, but the long charging time is a disadvantage for warehouses operating 24 hours a day. Some forklifts are fitted with fuel cells that charge the battery while the vehicle is in use. The battery can be made smaller but not eliminated because the fuel cell has poor power delivery and has a sluggish ramp-up on demand; the battery remains the primary power source.
The heavier the wheeled application is, the less suitable the battery becomes. This does not prevent engineers from looking into large battery systems to replace the polluting internal combustion engine (ICE). One such application is the Automatic Guided Vehicle (AGV) system at ship ports. AGVs run 24 hours a day and the vehicles cannot be tied up for lengthy charging intervals. Li-ion solves this in part by replacing the very large 10-ton, 300kWh lead acid with a battery that is lighter and can be charged more quickly. But very large batteries have a limitation because of weight, charging time and infrastructure and the fuel cell may solve large traction systems as described in BU-1005 if burning fossil fuel is not an option.
However, no economical battery solution exists yet for large traction systems and burning fossil fuel cannot be fully avoided. While a modern Li-ion battery delivers about 150Wh/kg of energy, the net calorific value (NCV) of fossil fuel is over 12,000Wh/kg. Even at the low 25-percent efficiency of an ICE engine, the energy from a battery is fractional compared to fossil fuel(See BU-1007: Net Calorific Value) Furthermore, the ICE can operate in extreme cold and heat, a task the battery struggles to meet.
Batteries for Aviation
The duty of batteries on board an aircraft is to feed navigation and emergency systems when the Auxiliary Power Unit (APU) is off or during an emergency in flight. The battery provides power for braking, ground operation and starting the APU. In the event of engine failure, the batteries must supply energy from 30 minutes to 3 hours. Each aircraft must also have enough battery power to facilitate a safe landing. During flight, the electrical power is supplied by generators and, similar to a car, the on-board battery could be disconnected if so required.
Most commercial jetliners use flooded nickel-cadmium. Starting a large aircraft begins by spooling the APU, a small turbine engine located at the tail section of an airplane. This takes significantly longer and requires more energy than cranking a reciprocating engine of similar size. The spooling speed of the APU must be sufficiently high to attain compression for self-sustained ignition. Starting takes about 15 seconds and consumes 15kW of energy. Once running, an air compressor or hydraulic pump jumpstarts the large jet engines one-by-one.
Smaller aircraft often have sealed lead-acid. Although heavier than NiCd, lead acid requires less maintenance. The 12 and 24V aviation batteries are rated in IPP (current peak power)* and IPR (current power rating)** rather than CCA (cold cranking amps) as is common in the automotive industry. IPP and IPR are the International Electrotechnical Commission (IEC 60952-1) standard for aircraft batteries and FAA TSO-C173 that allow a battery to spool each engine for 25–40 seconds at high current.
Modern jet fighters spool the jet engines with Li-ion, so does the Boeing 787 Dreamliner. The Airbus 350 offers the option of either chemistry. As the on-board functions of an airliner move from hydraulic to electrical, larger batteries are required. The higher energy-dense Li-ion satisfies this demand better than NiCd and lead acid. However, unexpected Li-ion failure with serious consequences may move airplane makers back to NiCd. All batteries are subject to breakdowns; there are also reported heat failures with NiCd, but these can be better managed than Li-ion.
NiCd provides durability and reliable service, but it needs high maintenance that includes exercising the battery to eliminate memory. The service of the main-ship battery consists of a total discharge and shorting each cell for 24 hours with a strap. The battery is also checked for capacity with a battery analyzer. Smaller NiCd batteries have different service requirements.
Although aircraft carry many different batteries aboard, their sole purpose is to start the engine and provide backup power when the engines are off. Large aircraft will continue to fly on fossil fuel as batteries are not yet practical for propulsion. Small battery-powered airplanes are being tried for pilot training and to fly short hops but these are experimental only. Weight and reliability on an aging battery remain major concerns.
| *Ipp: | Peak current delivered at 0.3 seconds into a 15 second controlled discharge at a constant terminal voltage of half the nominal battery voltage. |
| **Ipr: | This is the discharge current at the conclusion of a 15 second controlled discharge at a constant terminal voltage of half the nominal battery voltage. |
Batteries for Aerospace
Early satellites used NiCd batteries, and this led to the discovery of the “memory” phenomenon. The battery followed a routine discharge schedule but when more energy was demanded, the battery could remember. The voltage would drop as if to protest against unwanted overtime.
NiCd was replaced by nickel-hydrogen as a battery with an exceptional long service life. Entrepreneurs tried to introduce this amazing battery for commercial use but high price and large size spoiled market acceptance. Each cell costs around $1,000 and has the appearance of a small steam engine with a steel pressure tank.
Li-ion is the battery of choice for satellites. It is light-weight, easy to charge, durable and cycles well. Li-ion can dwell in any SoC for an extended length of time without adverse side effects; it has low self-discharge and is virtually maintenance free.
The Mars Curiosity Rover uses specially designed lithium nickel oxide cells (LiNiCo) in 8S2P formation (eight cells in series and two in parallel) that is only partially charged and discharged to stretch longevity. Under this regime, the life span is four years and roughly 700 sol. (The term sol is used by planetary astronomers to refer to the duration of a solar day on Mars.) The 43Ah cells, of which two are in parallel, have a maximum discharge C-rate of 0.55C.
NASA wants Li-ion batteries to last for 7 years and 37,000 cycles with a DoD of 40 to 60 percent. NASA labs reveal that end-of-life is connected with the growth of the SEI layer on the anode, loss of cathode material, loss of conductive path, plating of metallic lithium and electrolyte oxidation. Large 140Ah Li-ion cells are in development that promise to last up to 18 years(See also BU-808B: What causes Li-ion to die?)
Stationary Batteries
With a growing choice of batteries for energy storage systems (ESS), the selection should not be based on price alone. Cost per kWh says little without also examining the total cost of ownership that includes cost per cycle, longevity and eventual replacement.
Lead acid is well suited for duties that need only occasional discharges. The flow battery and sodium-sulfur battery work well for large systems requiring regimented discharges, while lithium ion is recommended for small to medium systems delivering short discharging with fast charging ability multiple times a day.
Traditionally, stationary batteries have been lead acid. Size and weight is of lesser concern, and the limited cycle count does not pose a problem when the batteries are seldom discharged. Large stationary batteries are mostly flooded and require regular checking of the electrolyte level. This maintenance can be reduced with an automatic watering system.
Valve-regulated lead acid (VRLA) is the low-maintenance version of the flooded lead acid. It is said that VRLA can be installed and forgotten, but this is often taken to the extreme in that the batteries get neglected. Maintenance includes checking the voltage, internal resistance and sometimes capacity levels.
Applications that are exposed to hot and cold temperatures as well as those requiring deep cycling are often served by flooded nickel-cadmium. These batteries are more rugged than lead acid but are roughly four times the cost. Flooded nickel-cadmium batteries are non-sintered and are less subject to memory that the sintered versions, which are sealed, but some maintenance is still required. NiCd is the only battery that can be rapidly charged with minimal stress.
Many stationary batteries are also served by Li-ion. Li-ion comes with many advantages, but the battery does not perform as well as NiCd and lead acid at low temperature. Another battery that is making a comeback for stationary use is nickel-iron. Inventor Thomas Edison promoted NiFe for the electric vehicle, but it eventually lost out to lead acid due to high cost and high self-discharge. Improvements have eliminated some of the failings, and the superior durability of this battery is gaining renewed interest.
Energy Storage Systems (Grid Storage Batteries)
Renewable energy sources such as wind and sun do not provide a steady stream of energy, nor do they always harmonize with user demand. Large energy storage systems (ESS) called load leveling or grid storage batteries are needed to provide a seamless service.
ESS enjoys a large growth trajectory to move from coal and oil to renewable resources. ESS installations in South Africa alone are estimated to reach 1,500MWh by 2021. Chemistries under consideration are flow batteries, Li-ion, lead acid and zinc-bromine. Zinc-bromine is a type of hybrid flow battery that can be regarded as an electroplating machine. During charge, zinc electroplates onto conductive electrodes forming bromine; the process reverses on discharge. Another leading ESS battery is the high temperature sodium-sulfur battery.
Storing energy to supply peak shaving power is not new. Hydroelectric power stations use excess electricity to pump water back up to the reservoir at night for use the next day. With an efficiency factor of 70–85 percent, pumped hydro is easier to manage than adjusting the generators to the exact power need. Pumping compressed air into large underground cavities and underwater balloons are also being used to store energy.
Flywheels also serve as energy storage. Large electric motors rev up one-ton flywheels when excess energy is available to supply brief energy deficiencies. High-speed flywheels spin at over 30,000 rpm on magnetic bearings in a vacuum chamber. Electric motors/generators with permanent magnets charge and discharge the kinetic energy on demand.
Modern flywheels replace steel with carbon fibers to withstand higher rotations of up to 60,000 rpm. Energy increases by the square of speed, providing four times the power at a reduced weight. Should the flywheel fail, the housing prevents shrapnel form escaping.
Using flywheels to store kinetic energy is not new. In the 1940s and 1950s, city busses in Switzerland were powered by flywheels. An electric motor would spin a 3-ton flywheel to 3,000 rpm in 3 minutes. Turning into a generator, the motor would then transform the energy back into electricity. Each charge would yield for 6km (3.75mi) on a flat road. The bus was pollution-free but the gyroscope action resisted changing direction on a windy road.
Load leveling is gravitating towards Li-ion because of small footprint, low maintenance and long life. Li-ion does not suffer from sulfation as lead acid does when not fully charged periodically. This can be a major drawback with installations when demand exceeds supply. Li-ion also has the benefit of being light-weight and semi-portable for installations in remote locations. The negatives of Li-ion are its high price and low performance at cold temperature. A further drawback is the inability to charge below freezing.
Li-ion has come down in price and Table 1 provides a cost comparison with lead acid for grid storage applications. Although the initial price of Li-ion is higher than lead acid, the cost per cycle is lower in deep-cycle applications. Li-ion is said to gain in market share but lead acid will keep its stronghold.
| Lead acid | Li-ion | |
|---|---|---|
| Battery cost | $20,000 | $52,000 |
| Lifespan | 500 cycles at 50% DoD | 1,900 cycles at 90% DoD |
| Cost per cycle | $40 | $28 |
Table 1: Cost comparison of lead acid and Li-ion for renewable energy [1]
Li-ion has a higher initial cost but is lower on the cost per cycle. Prices are estimated.
The energy output of a large industrial wind turbine is 1 megawatt (MW) and more; the biggest units have grown to 10MW. Several turbines form a wind farm that produces 30–300MW. To fathom a megawatt, 1MW feeds 50 houses or a Walmart superstore.
Not all renewable energy systems include load leveling batteries. The batteries simply get too large and the investment cannot always be justified. If supported by batteries, a 30MW wind farm uses a storage battery of about 15MW. This is the equivalent of 20,000 starter batteries or 176 Tesla S 85 EVs with an 85kWh battery each. The cost to store energy in a battery is high, and some say it doubles the cost to a direct supply.
The battery management system (BMS) keeps the battery at about 50 percent charge to allow absorbing energy on wind gusts and delivering on high load demands. Modern BMS can switch from charge to discharge in less than a second. This helps stabilize the voltage on transmission lines, also known as frequency regulation.
References
[1] Courtesy: http://www.powertechsystems.eu...
Last Updated: 4-Nov-2021
Batteries In A Portable World
The material on Battery University is based on the indispensable new 4th edition of "Batteries in a Portable World - A Handbook on Rechargeable Batteries for Non-Engineers" which is available for order through Amazon.com.
Find An Article
Table of Contents
-
Introduction 4>
- BU-001: Sharing Battery Knowledge
- BU-002: Introduction
- BU-003: Dedication
-
Crash Course on Batteries 4>
- BU-101: When Was the Battery Invented?
- BU-102: Early Innovators
- BU-103: Global Battery Markets
- BU-103a: Battery Breakthroughs: Myth or Fact?
- BU-104: Getting to Know the Battery
- BU-104a: Comparing the Battery with Other Power Sources
- BU-104b: Battery Building Blocks
- BU-104c: The Octagon Battery – What makes a Battery a Battery
- BU-105: Battery Definitions and what they mean
- BU-106: Advantages of Primary Batteries
- BU-106a: Choices of Primary Batteries
- BU-107: Comparison Table of Secondary Batteries
-
Battery Types 4>
- BU-201: How does the Lead Acid Battery Work?
- BU-201a: Absorbent Glass Mat (AGM)
- BU-201b: Gel Lead Acid Battery
- BU-202: New Lead Acid Systems
- BU-203: Nickel-based Batteries
- BU-204: How do Lithium Batteries Work?
- BU-205: Types of Lithium-ion
- BU-206: Lithium-polymer: Substance or Hype?
- BU-208: Cycling Performance
- BU-209: How does a Supercapacitor Work?
- BU-210: How does the Fuel Cell Work?
- BU-210a: Why does Sodium-sulfur need to be heated
- BU-210b: How does the Flow Battery Work?
- BU-211: Alternate Battery Systems
- BU-212: Future Batteries
- BU-214: Summary Table of Lead-based Batteries
- BU-215: Summary Table of Nickel-based Batteries
- BU-216: Summary Table of Lithium-based Batteries
- BU-217: Summary Table of Alternate Batteries
- BU-218: Summary Table of Future Batteries
-
Packaging and Safety 4>
- BU-301: A look at Old and New Battery Packaging
- BU-301a: Types of Battery Cells
- BU-302: Series and Parallel Battery Configurations
- BU-303: Confusion with Voltages
- BU-304: Why are Protection Circuits Needed?
- BU-304a: Safety Concerns with Li-ion
- BU-304b: Making Lithium-ion Safe
- BU-304c: Battery Safety in Public
- BU-305: Building a Lithium-ion Pack
- BU-306: What is the Function of the Separator?
- BU-307: How does Electrolyte Work?
- BU-308: Availability of Lithium
- BU-309: How does Graphite Work in Li-ion?
- BU-310: How does Cobalt Work in Li-ion?
- BU-311: Battery Raw Materials
-
Charge Methods 4>
- BU-401: How do Battery Chargers Work?
- BU-401a: Fast and Ultra-fast Chargers
- BU-402: What Is C-rate?
- BU-403: Charging Lead Acid
- BU-404: What is Equalizing Charge?
- BU-405: Charging with a Power Supply
- BU-406: Battery as a Buffer
- BU-407: Charging Nickel-cadmium
- BU-408: Charging Nickel-metal-hydride
- BU-409: Charging Lithium-ion
- BU-409a: Why do Old Li-ion Batteries Take Long to Charge?
- BU-409b: Charging Lithium Iron Phosphate
- BU-410: Charging at High and Low Temperatures
- BU-411: Charging from a USB Port
- BU-412: Charging without Wires
- BU-413: Charging with Solar, Turbine
- BU-413a: How to Store Renewable Energy in a Battery
- BU-414: How do Charger Chips Work?
- BU-415: How to Charge and When to Charge?
-
Discharge Methods 4>
- BU-501: Basics about Discharging
- BU-501a: Discharge Characteristics of Li-ion
- BU-502: Discharging at High and Low Temperatures
- BU-503: Determining Power Deliver by the Ragone Plot
- BU-504: How to Verify Sufficient Battery Capacity
-
"Smart" Battery 4>
- BU-601: How does a Smart Battery Work?
- BU-602: How does a Battery Fuel Gauge Work?
- BU-603: How to Calibrate a “Smart” Battery
- BU-603a: Calibrating SMBus Batteries with Impedance Tracking
- BU-604: How to Process Data from a “Smart” Battery
- Testing and Calibrating Smart Batteries
-
From Birth to Retirement 4>
- BU-701: How to Prime Batteries
- BU-702: How to Store Batteries
- BU-703: Health Concerns with Batteries
- BU-704: How to Transport Batteries
- BU-704a: Shipping Lithium-based Batteries by Air
- BU-704b: CAUTION & Overpack Labels
- BU-704c: Class 9 Label
- BU-704d: NFPA 704 Rating
- BU-704e: Battery for Personal and Fleet Use
- BU-705: How to Recycle Batteries
- BU-705a: Battery Recycling as a Business
- BU-706: Summary of Do's and Don'ts
-
How To Prolong Battery Life 4>
-
General 4>
- BU-801: Setting Battery Performance Standards
- BU-801a: How to Rate Battery Runtime
- BU-801b: How to Define Battery Life
- BU-802: What Causes Capacity Loss?
- BU-802a: How does Rising Internal Resistance affect Performance?
- BU-802b: What does Elevated Self-discharge Do?
- BU-802c: How Low can a Battery be Discharged?
- BU-803: Can Batteries Be Restored?
- BU-803a: Cell Matching and Balancing
- BU-803b: What causes Cells to Short?
- BU-803c: Loss of Electrolyte
-
Lead Acid 4>
- BU-804: How to Prolong Lead-acid Batteries
- BU-804a: Corrosion, Shedding and Internal Short
- BU-804b: Sulfation and How to Prevent it
- BU-804c: Acid Stratification and Surface Charge
- BU-805: Additives to Boost Flooded Lead Acid
- BU-806: Tracking Battery Capacity and Resistance as part of Aging
- BU-806a: How Heat and Loading affect Battery Life
-
Nickel-based 4>
- BU-807: How to Restore Nickel-based Batteries
- BU-807a: Effect of Zapping
-
Lithium-ion 4>
- BU-808: How to Prolong Lithium-based Batteries
- BU-808a: How to Awaken a Sleeping Li-ion
- BU-808b: What Causes Li-ion to Die?
- BU-808c: Coulombic and Energy Efficiency with the Battery
- BU-809: How to Maximize Runtime
- BU-810: What Everyone Should Know About Aftermarket Batteries
- BU-811: Assuring Minimum Operational Reserve Energy (MORE)
-
Battery Testing and Monitoring 4>
- BU-901: Fundamentals in Battery Testing
- BU-901b: How to Measure the Remaining Useful Life of a Battery
- BU-902: How to Measure Internal Resistance
- BU-902a: How to Measure CCA
- BU-903: How to Measure State-of-charge
- BU-904: How to Measure Capacity
- BU-905: Testing Lead Acid Batteries
- BU-905a: Testing Starter Batteries in Vehicles
- BU-905b: Knowing when to Replace a Starter Battery
- BU-906: Testing Nickel-based Batteries
- BU-907: Testing Lithium-based Batteries
- BU-907a: Battery Rapid-test Methods
- BU-907b: Advancements in Battery Testing
- BU-907c: Cloud Analytics in Batteries
- BU-908: Battery Management System (BMS)
- BU-909: Battery Test Equipment
- BU-910: How to Repair a Battery Pack
- BU-911: How to Repair a Laptop Battery
- BU-915: Testing Battery with EIS
- BU-916: Deep Battery Diagnostics
- BU-917: In Search for Performance Transparency with Batteries
- BU-918: Battery Endurance Plan
-
Amazing Value of a Battery 4>
- BU-1001: Batteries in Industries
- BU-1002: Electric Powertrain, then and now
- BU-1002a: Hybrid Electric Vehicles and the Battery
- BU-1002b: Environmental Benefit of the Electric Powertrain
- BU-1003: Electric Vehicle (EV)
- BU-1003a: Battery Aging in an Electric Vehicle (EV)
- BU-1004: Charging an Electric Vehicle
- BU-1005: Does the Fuel Cell-powered Vehicle have a Future?
- BU-1006: Cost of Mobile and Renewable Power
- BU-1007: Net Calorific Value
- BU-1008: Working towards Sustainability
- BU-1009: Battery Paradox - Afterword
-
Information 4>
- BU-1101: Glossary
- BU-1102: Abbreviations
- BU-1103: Bibliography
- BU-1104: About the Author
- BU-1105: About Cadex (Sponsor)
- BU-1106: Author's Creed
- BU-1107: Disclaimer
- BU-1108: Copyright
-
Learning Tools 4>
- BU-1501 Battery History
- BU-1502 Basics about Batteries
- BU-1503 How to Maintain Batteries
- BU-1504 Battery Test & Analyzing Devices
- BU-1505 Short History of Cadex
-
Battery Articles 4>
- Perception of a Battery Tester
- Green Deal
- Risk Management in Batteries
- Predictive Test Methods for Starter Batteries
- Why Mobile Phone Batteries do not last as long as an EV Battery
- Battery Rapid-test Methods
- How to Charge Li-ion with a Parasitic Load
- Ultra-fast Charging
- Assuring Safety of Lithium-ion in the Workforce
- Diagnostic Battery Management
- Tweaking the Mobile Phone Battery
- Battery Test Methods
- Battery Testing and Safety
- How to Make Battery Performance Transparent
- Battery Diagnostics On-the-fly
- Making Battery State-of-health Transparent
- Batteries will eventually die, but when and how?
- Why does Pokémon Go rob so much Battery Power?
- How to Care for the Battery
- Tesla’s iPhone Moment — How the Powerwall will Change Global Energy Use
- Painting the Battery Green by giving it a Second Life
- Charging without Wires — A Solution or Laziness
- What everyone should know about Battery Chargers
- A Look at Cell Formats and how to Build a good Battery
- Battery Breakthroughs — Myth or Fact?
- Rapid-test Methods that No Longer Work
- Shipping Lithium-based Batteries by Air
- How to make Batteries more Reliable and Longer Lasting
- What causes Lithium-ion to die?
- Safety of Lithium-ion Batteries
- Recognizing Battery Capacity as the Missing Link
- Managing Batteries for Warehouse Logistics
- Caring for your Starter Battery
- Giving Batteries a Second Life
- How to Make Batteries in Medical Devices More Reliable
- Possible Solutions for the Battery Problem on the Boeing 787
- Impedance Spectroscopy Checks Battery Capacity in 15 Seconds
- How to Improve the Battery Fuel Gauge
- Examining Loading Characteristics on Primary and Secondary Batteries
-
Language Pool 4>
- BU-001: Compartir conocimiento sobre baterías
- BU-002: Introducción
- BU-003: Dedicatoria
- BU-104: Conociendo la Batería
- BU-302: Configuraciones de Baterías en Serie y Paralelo
-
Batteries in a Portable World book 4>
- Change-log of “Batteries in a Portable World,” 4th edition: Chapters 1 - 3
- Change-log of “Batteries in a Portable World,” 4th edition: Chapters 4 - 10